爱普生绘图仪非常规报错代码

SC-T3280 ;SC-T5080 ;SC-T3080 ;SC-T5280 ;SC-T5280D ;SC-T7080 ;SC-T7280 ;SC-T7280D ;SC-P10080 ;SC-P6080 ;SC-P7080 ;SC-P20080 ;SC-P8080 ;SC-P9080 ;SC-F6080 ;SC-B7080

CodeProductCategoryError NameCauseCheck ItemRemedy
D135SC-B7000 seriesControl BoardCommunication error between Main board and SUB boardCommunication error between Main board and SUB board occurs.Check the connection of the connector and/or the defect of the cable between Main board and SUB board.1. Reconnect the FCC between Main board and SUB board
2. Replace the FFC between Main board and SUB board
3. Replace the SUB board
4. Replace the Main board
D165SC-T7200 seriesHardwareNVRAM writing errorIllegal data was written in the NVRAM when replaced the Main board.Check the data to written in the NVRAM.1. Rewrite the NVRAM
2. Replace the Main board
D165SC-T3200 seriesOtherInvalid operationPanel operation and Copy Manager operation were done at same time.The error occurs when select "Scan and save" by panel operation and then "Start scan" by CopyManager.Operate one side only, panel operation or CopyManager operation.
D233SC-P10000 series,
SC-P20000 seriesDataPRN data errorIllegal data in the PRN fileCheck if the RIP version is the latest.1. Use latest RIP version
2. Send RIP information and PRN file to SEC for analysis
D237SC-F6000 seriesCRCR Scale or CR Encoder errorIllegal signal from the CR Scale or CR Encoder1. Check the CR Scale if it has any dirt or damage.
2. Check the CR Encoder if it has any dirt or damage.1. Clean the CR Scale and the CR Encoder
2. Replace the CR Scale
3. Replace the CR Encoder
D246SC-T3000 series,
SC-T5000 series,
SC-T7000 seriesSensorPE Sensor errorPE Sensor detected illegal value.Check the paper1. Check with Epson standard paper
2. Adjust rear AD
3. Replace PE Sensor
D390SC-F2000 seriesDataPRN file name errorReceived illegal PRN file name. (e.g. File name error or Character code error)Check the PRN file name (less than 255 characters or illegal character code.)Change the PRN file name
D420SC-T7200D seriesHardwareHDD write errorWrote illegal data to the HDD.Check the wrote data.1. Change the data
2. Format the HDD
3. Replace the HDD
E25FSC-P6000 series,
SC-P20000 seriesDataPRN file errorReceived illegal PRN file (used PRN file for other printer)1. Check the send data
2. Check the RIP version1. Correct the data
2. Version up the RIP
D3DDSC-P10000 series,
SC-P20000 series,
SC-P9000 series,
SC-P8000 series,
SC-P7000 series,
SC-P6000 seriesDataImage processing errorIllegal image data is reveived due to USB data conflict.1. Check if multiple jobs are sent from different applications in one time (Ex. Mirage RIP and Photoshop). 2. Check if backgroud application is used during printing (Ex. Mirage RIP and LFP Accounting Tool).1. Not to send the multiple print jobs from different applications.
2. Change the printer connection via LAN.
3. Quit the application which communicate to the printer in backgroud.
D91ASC-P9000 series,
SC-P8000 series,
SC-P7000 series,
SC-P6000 seriesHardwareWaiting for completion of flushing Timeout error· CR has not moved to the completion position of flushing.
· The CR motor is not moving due to some trouble.1. Encoder scale dirt for CR motor
2. Load and breakage of CR motor,1. Cleaning the encoder scale for CR motor
2. Change the encoder scale for CR motor
3. Replacing the CR motor
E89FSC-P9000 series,
SC-P8000 series,
SC-P7000 series,
SC-P6000 seriesHardwareTimeout errorTimeout of CR movementCheck the CR Scale if it has any dirt or damage1. Clean the CR Scale and the CR Encoder
2. Replace the CR Scale
D000SC-P10000 series,
SC-P20000 series,
SC-T3200 series,
SC-T5200 series,
SC-T7200 seriesMain boardCPU errorCPU error at firmware start upElectrical contact failure of Main board to other boardCheck the connection of all FFCs from main board to other board especially control panel
D918SC-T3200 series,
SC-T5200 series,
SC-T7200 series,
SC-P10000 series,
SC-P20000 seriesHardwareTime out error Time out error related CR Scale or CR Encoder1. Check the CR Scale if it has any dirt or damage.
2. Check the CR Encoder if it has any dirt or damage.1. Clean the CR Scale and the CR Encoder
2. Replace the CR Scale
3. Replace the CR Encoder
1531SC-T3200 series,
SC-T5200 series,
SC-T7200 seriesHardwarePressure Roller release error1. When the pressure roller sensor breaks down
2. When the sensor cannot be physically detectedCheck the pressure roller sensor if it has any dirt or damage.1. Clean the pressure roller sensor
2. Replace the pressure roller sensor